DOI 10.1016/j.ejogrb.2019.04.003
Accuracy of clinical breast examination's abnormalities for breast cancer screening: cross-sectional study.
Аннотация
OBJECTIVES
The guidelines for breast cancer screening with clinical breast examination (CBE) are diverging CBE is recommended in France, whereas it is not recommended in the United States and Canada, given the lack of clear benefit and the risk of overmedication. To assess the accuracy of abnormalities found during CBE for in breast cancer screening.
STUDY
DESIGN
A cross-sectional study included women over 18 years with no history of breast cancer coming for a mammography at 3 ambulatory radiology practices in Paris. A questionnaire collected the risk of breast cancer on mammography according to the Breast Imaging-Reporting And Data System (Bi-RADS) (high risk: Bi-RADS 4 or 5 versus lower risk: other Bi-RADS categories), the risk factors for breast cancer and the breast clinical abnormalities (none, mass, skin abnormality, oedema, pain, nipple discharge, lymph nodes…) For each abnormality, sensitivity, specificity, positive (PPV) and negative (NPV) predictive values were calculated.
RESULT: Among the 3218 included patients (mean age 55.1 +/-10 years), 713 (22.2%) had an abnormal CBE and 133 (4.1%) had high-risk mammography. The sensitivity of CBE was 36%[28%;45%] and the specificity was 78%[77%;80%]. The PPV and NPV for each clinical abnormality were low, except for nipple discharge, retraction and lymph nodes, for which the PPV were 10.5[3.7;29.9], 6.6[1.4;31.6], and 5.0[1.5;17.1], respectively, but these abnormalities were rare (0.5%, 0.2% and 0.5% respectively). These values were similar across all age groups.
CONCLUSION
The accuracy of CBE for breast cancer screening appeared to be low which did not support recommending regular CBE in France.