MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.thromres.2014.02.031

Медицинская библиотека · Thrombosis research · 2014

Mechanical heart valve prosthesis and warfarin - treatment quality and prognosis.

Grzymala-Lubanski Bartosz, Labaf Ashkan, Englund Erling, Svensson Peter J, Själander Anders

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Every year about 2500 patients in Sweden undergo surgery due to heart valve disease. A mechanical heart valve prosthesis causes risk of thromboembolic stroke or thrombus formation in the valve while anticoagulant treatment increases the risk of bleeding. Treatment quality with warfarin is crucial for patients with mechanical valve prostheses. It has previously been shown that poorly controlled warfarin treatment increases mortality in this patient group. TTR (Time in Therapeutic Range) on warfarin has been shown to affect the risk of complications in atrial fibrillation, but has not been studied in patients with mechanical heart valves. Our aim is to evaluate the impact of TTR on the risk of complications in this patient group.

MATERIALS AND

METHODS

A non-randomized, prospective study of 534 adults with mechanical heart valve prostheses from Malmö and Sundsvall registered in the Swedish National Quality Registry Auricula between 01.01.2008 and 31.12.2011. Quartiles regarding individual TTR levels were compared regarding risk of complications.

RESULTS

The risk of complications was significantly higher at lower TTR levels for all complications (p=0.005), bleeding (p=0.01) and death (p=0.018) but not for thromboembolism. In multivariate analysis the risk was significantly increased at lower TTR levels for bleeding and all complications but not for death or thromboembolism.

CONCLUSION

Patients with a lower warfarin treatment quality measured by TTR have a higher risk of complications such as severe bleeding or death. A TTR of 83% or higher at the individual level should be obtained for best outcome.

Для цитирования: Grzymala-Lubanski Bartosz, Labaf Ashkan, Englund Erling, Svensson Peter J, Själander Anders. Mechanical heart valve prosthesis and warfarin - treatment quality and prognosis.. Thrombosis research. 2014. DOI: 10.1016/j.thromres.2014.02.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.