MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jon.12342

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2016

3D Super-Resolution Motion-Corrected MRI: Validation of Fetal Posterior Fossa Measurements.

Pier Danielle B, Gholipour Ali, Afacan Onur, Velasco-Annis Clemente, Clancy Sean, Kapur Kush, Estroff Judy A, Warfield Simon K

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: Current diagnosis of fetal posterior fossa anomalies by sonography and conventional MRI is limited by fetal position, motion, and by two-dimensional (2D), rather than three-dimensional (3D), representation. In this study, we aimed to validate the use of a novel magnetic resonance imaging (MRI) technique, 3D super-resolution motion-corrected MRI, to image the fetal posterior fossa.

METHODS

From a database of pregnant women who received fetal MRIs at our institution, images of 49 normal fetal brains were reconstructed. Six measurements of the cerebellum, vermis, and pons were obtained for all cases on 2D conventional and 3D reconstructed MRI, and the agreement between the two methods was determined using concordance correlation coefficients. Concordance of axial and coronal measurements of the transcerebellar diameter was also assessed within each method.

RESULTS

Between the two methods, the concordance of measurements was high for all six structures (P < .001), and was highest for larger structures such as the transcerebellar diameter. Within each method, agreement of axial and coronal measurements of the transcerebellar diameter was superior in 3D reconstructed MRI compared to 2D conventional MRI (P < .001).

CONCLUSIONS

This comparison study validates the use of 3D super-resolution motion-corrected MRI for imaging the fetal posterior fossa, as this technique results in linear measurements that have high concordance with 2D conventional MRI measurements. Lengths of the transcerebellar diameter measured within a 3D reconstruction are more concordant between imaging planes, as they correct for fetal motion and orthogonal slice acquisition. This technique will facilitate further study of fetal abnormalities of the posterior fossa.

Для цитирования: Pier Danielle B, Gholipour Ali, Afacan Onur, Velasco-Annis Clemente, Clancy Sean, Kapur Kush, Estroff Judy A, Warfield Simon K. 3D Super-Resolution Motion-Corrected MRI: Validation of Fetal Posterior Fossa Measurements.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2016. DOI: 10.1111/jon.12342.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.