DOI 10.1002/uog.2741

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2006

Dynamic cervical change: is real-time sonographic cervical shortening predictive of preterm delivery in patients with symptoms of preterm labor?

Jenkins S M, Kurtzman J T, Osann K

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To determine prospectively if dynamic cervical change (spontaneous real-time cervical shortening) is predictive of preterm delivery at < 37 weeks' gestation in patients with symptoms of preterm labor.

METHODS

This was a prospective study of patients at 23-34 weeks' gestation who were symptomatic for preterm labor. Patients underwent a 10-min real-time sonographic cervical length assessment with measurements taken at 1-min intervals. The presence or absence of dynamic cervical change, defined as real-time changes in cervical length observable to the naked eye of the sonologist during the examination, was recorded. Gestational age at delivery was obtained from medical records. Preterm delivery was defined as delivery at < 37 weeks' gestation. Dynamic cervical change and initial and minimum cervical lengths were assessed for prediction of preterm delivery.

RESULTS

Seventy-six patients were enrolled, and 66 were available for outcome analysis. Thirty-one patients (47%) exhibited dynamic cervical change. Patients with dynamic change had shorter initial cervical lengths (27 mm vs. 36 mm, P = 0.001), shorter minimum cervical lengths (20 vs. 33 mm, P < 0.001) and larger changes in cervical length during the examination period (10 vs. 4 mm, P < 0.001). In the subgroup of patients with an initial cervical length > 30 mm, those with dynamic change delivered earlier than did those without dynamic change (36.8 vs. 38.6 weeks, P = 0.02), and a higher percentage delivered preterm (27% vs. 11%, odds ratio (OR), 3.0 (0.5-17.0)). Multivariate analysis showed that minimum cervical length was a better predictor of preterm delivery than was initial cervical length.

CONCLUSIONS

Dynamic cervical change occurs frequently in association with shortened cervical length. In patients with longer initial cervical lengths, dynamic change may increase the risk for preterm delivery. When dynamic change is noted in a patient with preterm labor symptoms, use of the minimum cervical length observed may be better compared with initial cervical length for determining preterm delivery risk.

Для цитирования: Jenkins S M, Kurtzman J T, Osann K. Dynamic cervical change: is real-time sonographic cervical shortening predictive of preterm delivery in patients with symptoms of preterm labor?. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2006. DOI: 10.1002/uog.2741.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.