DOI 10.1097/aln.0000000000000074
A Metabolomic Approach to the Pathogenesis of Ventilator-induced Lung Injury.
Аннотация
BACKGROUND
Global metabolic profiling using quantitative nuclear magnetic resonance spectroscopy (MRS) and mass spectrometry (MS) is useful for biomarker discovery. The objective of this study was to discover biomarkers of acute lung injury induced by mechanical ventilation (ventilator-induced lung injury [VILI]), by using MRS and MS.
METHODS
Male Sprague-Dawley rats were subjected to two ventilatory strategies for 2.5 h: tidal volume 9 ml/kg, positive end-expiratory pressure 5 cm H2O (control, n = 14); and tidal volume 25 ml/kg and positive end-expiratory pressure 0 cm H2O (VILI, n = 10). Lung tissue, bronchoalveolar lavage fluid, and serum spectra were obtained by high-resolution magic angle spinning and H-MRS. Serum spectra were acquired by high-performance liquid chromatography coupled to quadupole-time of flight MS. Principal component and partial least squares analyses were performed.
RESULTS
Metabolic profiling discriminated characteristics between control and VILI animals. As compared with the controls, animals with VILI showed by MRS higher concentrations of lactate and lower concentration of glucose and glycine in lung tissue, accompanied by increased levels of glucose, lactate, acetate, 3-hydroxybutyrate, and creatine in bronchoalveolar lavage fluid. In serum, increased levels of phosphatidylcholine, oleamide, sphinganine, hexadecenal and lysine, and decreased levels of lyso-phosphatidylcholine and sphingosine were identified by MS.
CONCLUSIONS
This pilot study suggests that VILI is characterized by a particular metabolic profile that can be identified by MRS and MS. The metabolic profile, though preliminary and pending confirmation in larger data sets, suggests alterations in energy and membrane lipids.SUPPLEMENTAL DIGITAL CONTENT IS AVAILABLE IN THE TEXT.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.