BACKGROUND

There are limited data on the complications with a percutaneous left ventricular assist device (pLVAD) vs. intra-aortic balloon pump (IABP) in acute myocardial infarction-cardiogenic shock (AMI-CS).

OBJECTIVE

To assess the trends, rates and predictors of complications.

METHODS

Using a 17-year AMI-CS population from the National Inpatient Sample, AMI-CS admissions receiving pLVAD and IABP support were evaluated for vascular, lower limb amputation, hematologic, neurologic and acute kidney injury (AKI) complications. In-hospital mortality, hospitalization costs and length of stay in pLVAD and IABP cohorts with complications was studied.

RESULTS

Of 168,645 admissions, 7,855 (4.7%) receiving pLVAD support. The pLVAD cohort had higher comorbidity, cardiac arrest (36.1% vs. 29.7%) and non-cardiac organ failure (74.7% vs. 56.9%) rates. Complications were higher in pLVAD compared to IABP cohort-overall 69.0% vs. 54.7%; vascular 3.8% vs. 2.1%; lower limb amputation 0.3% vs. 0.3%; hematologic 36.0% vs. 27.7%; neurologic 4.9% vs. 3.5% and AKI 55.4% vs. 39.1% (all p<0.001 except for amputation). Non-White race, higher comorbidity, organ failure, and extracorporeal membrane oxygen use were predictors of complications for both cohorts. The pLVAD cohort with complications had higher in-hospital mortality (45.5% vs. 33.1%; adjusted odds ratio 1.65 [95% confidence interval 1.55-1.75]), shorter duration of hospital stay, and higher hospitalization costs compared to the IABP cohort with complications (all p<0.001). These results were consistent in propensity-matched pairs.

CONCLUSIONS

AMI-CS admissions receiving pLVAD had higher rates of complications compared to the IABP, with worse in-hospital outcomes in the cohort with complications.

Для цитирования: Vallabhajosyula Saraschandra, Subramaniam Anna V, Murphree Dennis H, Patlolla Sri Harsha, Ya'Qoub Lina, Kumar Vinayak, Verghese Dhiran, Cheungpasitporn Wisit, Jentzer Jacob C, Sandhu Gurpreet S, Gulati Rajiv, Shah Nilay D, Gersh Bernard J, Holmes David R, Bell Malcolm R, Barsness Gregory W. Complications from percutaneous-left ventricular assist devices versus intra-aortic balloon pump in acute myocardial infarction-cardiogenic shock.. PloS one. 2020. DOI: 10.1371/journal.pone.0238046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.