Clinical orthopaedics and related research · 2014

Effects of external rotation on anteroposterior translations in the shoulder: a pilot study.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Brown Andrew J, Debski Richard E, Voycheck Carrie A, McMahon Patrick J

Аннотация

BACKGROUND: Using physical examination to make the diagnosis of shoulder instability can be difficult, because typical examination maneuvers are qualitative, difficult to standardize, and not reproducible. Measuring shoulder translation is especially difficult, which is a particular problem, because measuring it inaccurately may result in improper treatment of instability.

QUESTIONS/PURPOSES: The objective of this study was to use a magnetic motion tracking system to quantify the effects of external rotation of the abducted shoulder on a simulated simple translation test in healthy subjects. Specifically, we hypothesized that (1) increasing external rotation of the abducted shoulder would result in decreasing translation; (2) intraobserver repeatability would be less than 2 mm at all external rotation positions; and (3) mean side-to-side differences would be less than 2 mm at all external rotation positions.

METHODS: The intraobserver repeatability and side-to-side differences of AP translation were quantified with a noninvasive magnetic motion tracking system and automated data analysis routine in nine healthy subjects at four positions of external rotation with the arm abducted. A shoulder positioning apparatus was used to maintain the desired arm position.

RESULTS: No differences in translations between the positions of external rotation were found (p = 0.48). Intraobserver repeatability was 1.1 mm (SD, 0.8 mm) and mean side-to-side differences were small: 2.7 mm (SD, 2.8 mm), 2.8 mm (SD, 1.8 mm), 2.5 mm (SD, 1.8 mm), and 4.0 mm (SD, 2.6 mm) at 0°, 20°, 40°, and 60° of external rotation, respectively.

CONCLUSIONS: The intraobserver repeatability was strong and the side-to-side differences in translation were small with the magnetic motion tracking system, which is encouraging for development of an improved quantitative test to assess shoulder translation for fast and low-cost diagnosis of shoulder instability.

CLINICAL RELEVANCE: Clinicians may not have to position the contralateral, normal, abducted shoulder in precisely the same position of external rotation as the injured shoulder while performing side-to-side comparisons.