MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0002-9378(97)70002-4

Медицинская библиотека · American journal of obstetrics and gynecology · 1997

Elevated second-trimester dimeric inhibin A levels identify Down syndrome pregnancies.

Wenstrom K D, Owen J, Chu D C, Boots L

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Our purpose was to determine whether second-trimester dimeric inhibin A levels distinguish Down syndrome pregnancies from euploid pregnancies.

STUDY

DESIGN

With use of a commercially available enzyme-linked immunosorbent assay (Serotec, Oxford) inhibin A medians were established in stored sera from 40 to 50 euploid pregnancies at each week of gestation from 14 to 20 weeks and from 33 Down syndrome pregnancies. Maternal serum alpha-fetoprotein, unconjugated estriol, and human chorionic gonadotropin levels measured in each sample before storage were retrieved. The performance of inhibin A in the multiple-marker screening test was evaluated.

RESULTS

The mean inhibin A multiple of the median was significantly higher in the Down syndrome group than in the euploid group (2.84 +/- 2.0 vs 1.22 +/- 1.0, p = 0.0001). An inhibin A level > or = 1.6 multiples of the median identified 70% of all Down syndrome pregnancies at a false-positive rate of 22%. Replacing estriol with inhibin A in the multiple-marker screening test resulted in a higher Down syndrome detection rate at a lower screen-positive rate.

CONCLUSION

Elevated second-trimester maternal serum inhibin A levels identify Down syndrome pregnancies; replacing estriol with inhibin A in the multiple-marker screening test improves test performance.

Для цитирования: Wenstrom K D, Owen J, Chu D C, Boots L. Elevated second-trimester dimeric inhibin A levels identify Down syndrome pregnancies.. American journal of obstetrics and gynecology. 1997. DOI: 10.1016/s0002-9378(97)70002-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.