MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2009.08.034

Медицинская библиотека · Journal of cataract and refractive surgery · 2010

Assessing the accuracy of intracameral antibiotic preparation for use in cataract surgery.

Lockington David, Flowers Hugh, Young David, Yorston David

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate 2 local dilution protocols to assess the accuracy and variability of intracameral antibiotic dosage in cataract surgery.

SETTING

Tennent Institute of Ophthalmology, Glasgow, United Kingdom.

METHODS

Ten ophthalmic operating room nurses from 2 local hospitals participated. Oven-dried analytical grade potassium chloride (KCl) was used as a surrogate for cefuroxime. Solutions intended for intracameral use (1.0 mg in 0.1 mL) were prepared according to the 2 protocols. Twenty samples were obtained for each protocol. Ten analytical chemists also performed both dilutions. Concentrations of KCl in each 0.1 mL sample were analyzed by flame photometry.

RESULTS

Thirty samples were obtained for each protocol. The median dose after dilution was 1.17 mg (range 0.62 to 1.77 mg) for protocol 1 and 2.05 mg (range 0.52 to 7.25 mg) for protocol 2. The median was significantly higher for protocol 2 (P < .001). There was also greater variability with protocol 2.

CONCLUSIONS

This study shows that the mathematical accuracy of a dilution protocol does not ensure dosage accuracy in the clinical scenario. Inadequate mixing in a 1.0 mL syringe was probably responsible for the inaccuracy of protocol 2, indicating that small-volume syringes should not be used for mixing. However, protocol 1 had an acceptable range of variability. Replication of this study could evaluate other protocols and address concerns regarding the accuracy of intracameral antibiotic preparations.

Для цитирования: Lockington David, Flowers Hugh, Young David, Yorston David. Assessing the accuracy of intracameral antibiotic preparation for use in cataract surgery.. Journal of cataract and refractive surgery. 2010. DOI: 10.1016/j.jcrs.2009.08.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.