DOI 10.1016/j.resp.2026.104603
A comparative evaluation of accuracy and response time in ear and finger pulse oximetry during repeated maximal breath-holding: Implications for safety.
Аннотация
INTRODUCTION
Pulse oximetry is widely used to monitor training intensity and define safety termination thresholds during breath-hold-related activities, yet its accuracy and response time vary by measurement site, reflecting inherent physiological differences between locations, such as perfusion and vascular tone. Because these physiological variables are markedly altered during breath-holding, this study investigated differences in pulse oximetry dynamics between central (ear) and peripheral (finger) sites during repeated maximal breath-holding.
METHODS
Forty healthy subjects performed three repeated maximal static breath-holds separated by 2-min rest intervals. Finger and earlobe SpO2, systemic cardiovascular variables, and gas exchange were assessed.
RESULTS
Breath-holds were terminated at progressively lower end-tidal oxygen and SpO2, and higher end-tidal carbon dioxide, arterial pressures, and cardiac output across successive attempts (p ≤ 0.003). SpO2 values at both the breaking point and nadir were consistently higher at the finger than at the earlobe (breaking point: +9-15%; nadir: +7-11%;p ≤ 0.008), with the inter-site differences being amplified across successive attempts (p ≤ 0.012). Finger SpO2 remained significantly higher at breaking point than at the nadir (+4-8%;p < 0.001), whereas no such differences were noted at the ear (p = 0.619). The time to reach SpO2 nadir was longer at the finger than at the earlobe (18-23 s;p < 0.001) and was extended across attempts only at the finger (from 27 s to 32 s;p < 0.001). Breath-hold duration correlated with the inter-site SpO2 differences at breakpoint (r = 0.53;p < 0.001).
CONCLUSIONS
Compared to earlobe measurement, finger pulse oximetry exhibited a consistent temporal delay, and systematically underestimated the severity of hypoxaemia. This divergence increased with longer breath-holds, indicating a duration-dependent amplification of the inter-site SpO2-measurement differences.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.