MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2009.05.029

Медицинская библиотека · American journal of ophthalmology · 2009

Effect of slow-releasing all-trans-retinoic acid in bioabsorbable polymer on delayed adjustable strabismus surgery in a rabbit model.

Lee Min Joung, Jin Su-Eon, Kim Chong-Kook, Choung Ho-Kyung, Kim Hwa Jung, Hwang Jeong-Min

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To determine the usefulness of slow-releasing all-trans-retinoic acid (ATRA) in polytetrafluoroethylene (PTFE)/polylactide-co-glycolide (PLGA) for delayed adjustable strabismus surgery.

DESIGN

Animal study.

METHODS

A prospective, masked-observer, controlled study was performed in 25 rabbits. Fifty rabbit eyes were divided randomly into three groups. After a recession of the superior rectus muscle, a PTFE/PLGA laminate containing ATRA, PTFE alone, or balanced salt solution was applied beneath and over the superior rectus muscle in the PTFE/PLGA/all-trans-retinoic acid group (ATRA group), the polytetrafluoroethylene group (PTFE group), and the control group, respectively. Delayed adjustment was performed once on each superior rectus muscle at 3 or 5 weeks after surgery by a masked observer.

RESULTS

In the control group, adjustment was possible in 2 of 5 eyes at 3 weeks after surgery and impossible in any eye at 5 weeks after surgery. In the PTFE and ATRA groups, adjustment was possible in all 10 eyes at 3 and 5 weeks after surgery. On comparing adjustability, a significant difference was observed between the PTFE group and the control group or between the ATRA group and the control group 5 weeks after surgery (P = .0003 and P = .0003, respectively). A significant difference was observed between the ATRA group and the control group in terms of adhesion between superior rectus muscles and sclerae at 5 weeks after surgery (P = .006).

CONCLUSIONS

Slow-releasing ATRA in PTFE/PLGA was found to reduce adhesion and to allow delayed adjustment in most eyes for up to 5 weeks after surgery.

Для цитирования: Lee Min Joung, Jin Su-Eon, Kim Chong-Kook, Choung Ho-Kyung, Kim Hwa Jung, Hwang Jeong-Min. Effect of slow-releasing all-trans-retinoic acid in bioabsorbable polymer on delayed adjustable strabismus surgery in a rabbit model.. American journal of ophthalmology. 2009. DOI: 10.1016/j.ajo.2009.05.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.