Bedside electrical impedance tomography to assist the management of pulmonary embolism: A case report.

Ding Chenling, Zhu Yibo, Zhang Shuyi, Zhao Zhanqi, Gao Yuan, Li Zhe

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Pulmonary embolism (PE) is a common worldwide disease with high mortality. Timely diagnosis and management of PE could significantly improve clinical outcomes. Electrical impedance tomography (EIT) is a novel noninvasive technique to monitor lung perfusion and help detect PE at the bedside. Here we present a case of clinical management of subsegmental PE with the help of the bilateral ventilation and perfusion(V/Q) asymmetry EIT image.

CASE PRESENTATION: A 72-year-old cancer patient with respiratory failure and acute kidney injury in the intensive care unit was suspected of PE based on his clinical manifestation. The contraindication of computed tomography pulmonary angiography (CTPA) for PE diagnosis prevented escalating anticoagulation therapy. Besides EIT ventilation and perfusion monitoring showed an abnormal asymmetry V/Q match between the bilateral lungs which promoted our decision to start systemic continuous anticoagulation therapy and improved the patient clinically. The following CTPA which clarified the diagnosis of PE suggests that the patient has benefited from our decision.

CONCLUSION

For critically ill patients with suspected PE, the asymmetry of the EIT V/Q image may provide crucial objective information for clinical management.

Для цитирования: Ding Chenling, Zhu Yibo, Zhang Shuyi, Zhao Zhanqi, Gao Yuan, Li Zhe. Bedside electrical impedance tomography to assist the management of pulmonary embolism: A case report.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e25159.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.