MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000046384

Медицинская библиотека · Medicine · 2025

Atrial overdrive pacing in drug-refractory postinfarction electrical storm case report.

Xu Xin-Yuan, He Rui-Xia, Wang Hai-Jun, Liu Peng, Ma Guo-Li, Ji Li-Na, Qi Ba-Ya-Er, Liu Xiao-Ping

СтатьяКлинический случайПеревод в очереди

Аннотация

RATIONALE: Drug-refractory electrical storm (ES) following acute myocardial infarction (AMI) constitutes a critical therapeutic challenge. Atrial overdrive pacing (AOP) provides physiological rhythm control by suppressing ventricular ectopy through synchronized atrioventricular activation, circumventing ventricular pacing-associated hemodynamic compromise.

PATIENT CONCERNS: A 62-year-old female with AMI developed recurrent polymorphic ventricular tachycardia/ventricular fibrillation refractory to antiarrhythmics (amiodarone/esmolol/lidocaine) and revascularization, fulfilling ES criteria.

DIAGNOSES: The patient was diagnosed with acute anterior wall myocardial infarction, Killip class II-III acute left heart failure, secondary hepatic dysfunction, hypertension, type 2 diabetes mellitus and ES.

INTERVENTIONS: X-ray-guided temporary AOP (95 bpm) via subclavian access was implemented with concurrent β-blocker/sacubitril-valsartan optimization and electrolyte correction. Antiarrhythmics were discontinued post-AOP.

OUTCOMES: Sustained arrhythmia suppression was achieved (0 recurrences/9 months), alongside improved left ventricular ejection fraction (40%→46%) and 70.7% N-terminal B-type natriuretic peptide precursor reduction (33,593→9839 pg/mL). Implantable cardioverter-defibrillator was declined without clinical sequelae.

LESSONS: AOP demonstrates dual therapeutic efficacy in refractory post-AMI ES: (1) physiological conduction restoration suppressing ectopic triggers and (2) avoidance of ventricular pacing-induced dyssynchrony. Fluoroscopic guidance ensures lead stability, positioning AOP as a hemodynamically favorable intervention in ES management.

Для цитирования: Xu Xin-Yuan, He Rui-Xia, Wang Hai-Jun, Liu Peng, Ma Guo-Li, Ji Li-Na, Qi Ba-Ya-Er, Liu Xiao-Ping. Atrial overdrive pacing in drug-refractory postinfarction electrical storm case report.. Medicine. 2025. DOI: 10.1097/md.0000000000046384.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.