BACKGROUND

The inadvertent lead malposition in the left heart (ILMLH) is an under-recognized event, which may complicate the implantation of cardiac electronic devices (CIEDs).

METHODS

We investigated the clinical conditions associated with ILMLH and the treatment strategies in these patients. We made a systematic review of the literature and identified 132 studies which reported 157 patients with ILMLH.

RESULTS

The mean age of patients was 68 years, and 83 were women. ILMLH was diagnosed, on average, 365 days after CIEDs implantation. Coexisting conditions were patent foramen ovale in 29% of patients, arterial puncture in 24%, perforation of the interatrial septum in 20%, atrial septal defect in 16% and perforation of the interventricular septum in 4%. At the time of diagnosis of ILMLH, 46% of patients were asymptomatic, 31% had acute TIA or stroke and 15% had overt heart failure. Overall, 14% of patients were receiving anticoagulants at the time of diagnosis of ILMLH. After diagnosis of ILMLH, percutaneous or surgical lead extraction was carried out in 93 patients (59%), whereas 43 (27%) received anticoagulation. During a mean 9-month follow-up after diagnosis of ILMLH, four patients experienced TIA or stroke (three on oral anticoagulant therapy and one after percutaneous lead extraction).

CONCLUSION

ILMLH is a rare complication, which is usually diagnosed about one year after implantation of CIEDs. An early diagnosis of ILMLH is important. Lead extraction is a safe and effective alternative to anticoagulants.

Для цитирования: Spighi Lorenzo, Notaristefano Francesco, Piraccini Silvia, Giuffrè Giuseppe, Barengo Alberto, D'Ammando Matteo, Notaristefano Salvatore, Bagliani Giuseppe, Zingarini Gianluca, Angeli Fabio, Verdecchia Paolo, Cavallini Claudio. Inadvertent Lead Malposition in the Left Heart during Implantation of Cardiac Electric Devices: A Systematic Review.. Journal of cardiovascular development and disease. 2022. DOI: 10.3390/jcdd9100362.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.