m+Medelevator.RU
← Поиск публикаций
Journal of dentistry · 2026

Assessing multimodal large language models for localizing dental implant fixtures on panoramic radiographs.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mine Yuichi, Taji Tsuyoshi, Takeda Saori, Okazaki Shota, Peng Tzu-Yu, Kakimoto Naoya, Murayama Takeshi

Аннотация

OBJECTIVES: To assess whether general-purpose multimodal large language models (LLMs) can localize dental implant fixtures on panoramic radiographs and to quantify false positives on implant fixture-absent images.

METHODS: Using an open-source dataset, we evaluated 82 implant fixture-present panoramic radiographs (297 fixtures) and 82 implant fixture-absent images balanced by present or absent radiopaque restorations (41 each). We tested three multimodal LLMs (GPT-4o, OpenAI o3, and GPT-5T) with a fixed visual-grounding prompt across five independent runs per image. We scored the outputs using an any-overlap rule within a free-response localization framework. The outcomes on the implant fixture-present images were fixture-level micro sensitivity, image-level complete detection rate (CDR), and false positives per image (FPPI+). The outcomes on the implant fixture-absent images were image-level specificity (no-box rate) and FPPI-.

RESULTS: On the implant fixture-present images, micro sensitivity was 16.97 % for GPT-4o, 68.82 % for OpenAI o3, and 65.66 % for GPT-5T; CDRs were 2.20 %, 59.02 %, and 56.59 %; and FPPI+ values were 3.83, 1.48, and 1.52, respectively. On the implant fixture-absent images, specificity values were 32.68 %, 65.85 %, and 68.54 %, and FPPI- values were 1.95, 1.04, and 0.92, respectively. Radiopaque restorations markedly reduced specificity. The fixtures detected in all five runs were 1.01 % (GPT-4o), 22.22 % (OpenAI o3), and 25.93 % (GPT-5T).

CONCLUSIONS: Reasoning-focused multimodal LLMs outperformed GPT-4o in zero-shot implant fixture localization and reduced false positives, but moderate sensitivity, restoration-driven errors, and run-to-run variability limit autonomous clinical use.

CLINICAL SIGNIFICANCE: This benchmark clarifies the current capabilities and limitations of multimodal LLMs for implant-related radiographic workflows.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты