A transformational change in scintigraphic gastroesophageal reflux studies: A comparison with historic techniques.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Burton Leticia, Joffe David, Mackey Douglas W, Van der Wall Hans, Falk Gregory L
Аннотация
BACKGROUND: The inclusion of scintigraphy in the diagnostic algorithm for gastroesophageal reflux is controversial due to variability in methodology and reporting. A novel scintigraphic reflux study has been developed and validated against the current standards for the diagnosis of gastroesophageal reflux disease (GORD).
OBJECTIVE: To compare a new scintigraphic reflux test against historic techniques and standardised diagnostic reference tests for gastroesophageal reflux disease.
METHODS: Paired scintigraphic studies were conducted in seventeen patients. All patients underwent at least one other standardised diagnostic reflux test such as 24- hour oesophageal impedance/ pH, and oesophageal manometry, barium swallow, gastroscopy or the Peptest. Patients inadvertently presented at sites B for scintigraphic reflux testing rather than at Site A which was part of an approved study. The findings from sites B did not correlate with clinical symptoms and other diagnostic reference tests from GORD. These studies were then repeated at Site A with approval from the patients. A second reflux study was performed at site A, utilising a novel technique with the capability of assessing oesophageal and extra-oesophageal disease.
RESULTS: The Site A technique shows good concordance with the reference diagnostic tests with an accuracy of 82.4% and kappa of 0.64 (SE: 0.16, p = 0.00). Site B had an overall accuracy of 47.1% and kappa of 0.066 (SE: 0.068, p = 0.45).
CONCLUSION: The Site A technique shows higher accuracy than either site B or the historic reflux techniques. It has characteristics that make it an effective screening tool for assessment of local oesophageal disease and its extraoesophageal manifestations.
OBJECTIVE: To compare a new scintigraphic reflux test against historic techniques and standardised diagnostic reference tests for gastroesophageal reflux disease.
METHODS: Paired scintigraphic studies were conducted in seventeen patients. All patients underwent at least one other standardised diagnostic reflux test such as 24- hour oesophageal impedance/ pH, and oesophageal manometry, barium swallow, gastroscopy or the Peptest. Patients inadvertently presented at sites B for scintigraphic reflux testing rather than at Site A which was part of an approved study. The findings from sites B did not correlate with clinical symptoms and other diagnostic reference tests from GORD. These studies were then repeated at Site A with approval from the patients. A second reflux study was performed at site A, utilising a novel technique with the capability of assessing oesophageal and extra-oesophageal disease.
RESULTS: The Site A technique shows good concordance with the reference diagnostic tests with an accuracy of 82.4% and kappa of 0.64 (SE: 0.16, p = 0.00). Site B had an overall accuracy of 47.1% and kappa of 0.066 (SE: 0.068, p = 0.45).
CONCLUSION: The Site A technique shows higher accuracy than either site B or the historic reflux techniques. It has characteristics that make it an effective screening tool for assessment of local oesophageal disease and its extraoesophageal manifestations.