MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm13154550

Медицинская библиотека · Journal of clinical medicine · 2024

Cerebrospinal Fluid Dynamics Analysis Using Time-Spatial Labeling Inversion Pulse (Time-SLIP) Magnetic Resonance Imaging in Mice.

Tomita Yusuke, Yagi Mitsuru, Seki Fumiko, Komaki Yuji, Matsumoto Morio, Nakamura Masaya

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Abnormalities in cerebrospinal fluid (CSF) dynamics cause diverse conditions, such as hydrocephalus, but the underlying mechanism is still unknown. Methods to study CSF dynamics in small animals have not been established due to the lack of an evaluation system. Therefore, the purpose of this research study is to establish the time-spatial labeling inversion pulse (Time-SLIP) MRI technique for the evaluation of CSF dynamics in mice.

Methods

We performed the Time-SLIP technique on 10 wild-type mice and 20 Tiptoe-walking Yoshimura (TWY) mice, a mouse model of ossification of the posterior longitudinal ligament (OPLL). We defined the stir distance as the distance of CSF stirring and calculated the mean ± standard deviation. The intraclass correlation coefficient of intraobserver reliability was also calculated. Furthermore, in TWY mice, the correlation coefficient between stir distance and canal stenosis ratio (CSR) was calculated.

Results

The stir distance was significantly lower in TWY mice at 12 weeks and 17 weeks of age (1.20 ± 0.16, 1.21 ± 0.06, and 1.21 ± 0.15 mm at 12 weeks and 1.32 ± 0.21, 1.28 ± 0.23, and 1.38 ± 0.31 mm at 17 weeks for examiners A, B, and C). The intrarater reliability of the three examiners was excellent (>0.90) and there was a strongly negative correlation between stir distance and CSR in TWY mice (>-0.80).

Conclusions

In this study, we established the Time-SLIP technique in experimental mice. This technique allows for a better understanding of CSF dynamics in small laboratory animals.

Для цитирования: Tomita Yusuke, Yagi Mitsuru, Seki Fumiko, Komaki Yuji, Matsumoto Morio, Nakamura Masaya. Cerebrospinal Fluid Dynamics Analysis Using Time-Spatial Labeling Inversion Pulse (Time-SLIP) Magnetic Resonance Imaging in Mice.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13154550.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.