Carpal tunnel syndrome: are the MR findings a result of population selection bias?
Аннотация
OBJECTIVE
Previous descriptions of MR imaging of carpal tunnel syndrome used limited study populations and volunteers as controls. We reevaluated these descriptions to determine their sensitivity and specificity when applied to a large consecutive clinical series in which the incidence of carpal tunnel syndrome was small.
SUBJECTS AND
METHODS
In 196 consecutive wrists for which supplemental axial conventional spin-echo T1-weighted and fast spin-echo T2-weighted images were obtained at 1.5 T with a dedicated wrist coil, 165 studies were available for review. Previously described signs of carpal tunnel syndrome such as proximally increased size, flattening of the median nerve, increased median nerve signal intensity, flexor tenosynovitis, retinacular bowing, decreased deep tendon fat, and deep palmar bursitis were retrospectively and independently evaluated by two observers who were unaware of patient diagnosis.
RESULTS
None of the previously described signs was sensitive for the diagnosis of carpal tunnel syndrome. However, specificity was high for retinacular bowing (94%), median nerve flattening (97%), and deep palmar bursitis (95%).
CONCLUSION
Most previously described MR imaging signs of carpal tunnel syndrome are insensitive and nonspecific. Exceptions include retinacular bowing, median nerve flattening, and deep palmar bursitis, which in our study proved to have specificities greater than or equal to 94%.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.