m+Medelevator.RU
← Поиск публикаций
Journal of dentistry · 2026

24-hour shrinkage behavior of ten resin-based composites.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Prowse Myles Andrew, Gareau Alexandre, MacNeil Brett D, DeWolf Darien, Price Richard B, Labrie Daniel

Аннотация

OBJECTIVE: To quantify the degree of conversion (DC), shrinkage strain, shrinkage stress, and polymerization kinetics of ten commercial resin-based composites (RBCs).

METHODS: Ten RBCs were tested. Four rapid-cure Tetric formulations (Tetric plus Fill, PowerFill, Tetric plus Flow, and PowerFlow) were photocured for 3 s at 3.0 W/cm² for DC and strain measurements and the corresponding stress specimens received 2.5 W/cm² for 3 s. Six comparator RBCs were photocured for 10 or 20 s at 1.2 W/cm² in accordance with their manufacturers' instructions. The DC was measured using ATR-FTIR on 0.2-mm-thick specimens for 720 s, whereas axial shrinkage strain and stress were recorded on 1.0-mm-thick specimens for 24 h. Because material and protocol were not varied independently, across-material comparisons were interpreted as intended-use comparisons rather than isolated formulation effects.

RESULTS: Tetric plus Fill and Tetric PowerFill produced comparable DC and 24 h shrinkage strain and stress. Among the regular-viscosity RBCs, Admira Fusion x-tra produced the lowest 24 h strain and stress. Tetric PowerFlow produced lower 24 h strain and stress than Tetric plus Flow. The rapid-cure Tetric material/protocol combinations exhibited earlier and larger DC-, strain-, and stress-rate peaks. Estelite Flow had a lower maximum DC rate and a broad, lower strain-rate peak, but it achieved the highest DC at 720 s and had a smaller late-time strain slope. In a regression constrained through the origin, the 24 h shrinkage stress increased with 24 h shrinkage strain under the tensometer geometry and compliance used in this study.

SIGNIFICANCE: The 24 h measurements show that low early shrinkage values may not predict the final material values and ranking.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты