MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jat/bkv001

Медицинская библиотека · Journal of analytical toxicology · 2015

Estimation of the Time Interval between the Administration of Heroin and the Sampling of Blood in Chronic Inhalers.

Dubois Nathalie, Hallet Claude, Seidel Laurence, Demaret Isabelle, Luppens David, Ansseau Marc, Rozet Eric, Albert Adelin, Hubert Philippe, Charlier Corinne

СтатьяПеревод в очереди

Аннотация

To develop a model for estimating the time delay between last heroin consumption and blood sampling in chronic drug users. Eleven patients, all heroin inhalers undergoing detoxification, were included in the study. Several plasma samples were collected during the detoxification procedure and analyzed for the heroin metabolites 6-acetylmorphine (6AM), morphine (MOR), morphine-6-glucuronide (M6G) and morphine-3-glucuronide (M3G), according to a UHPLC/MSMS method. The general linear mixed model was applied to time-related concentrations and a pragmatic four-step delay estimation approach was proposed based on the simultaneous presence of metabolites in plasma. Validation of the model was carried out using the jackknife technique on the 11 patients, and on a group of 7 test patients. Quadratic equations were derived for all metabolites except 6AM. The interval delay estimation was 2-4 days when only M3G present in plasma, 1-2 days when M6G and M3G were both present, 0-1 day when MOR, M6G and M3G were present and <2 h for all metabolites present. The 'jackknife' correlation between declared and actual estimated delays was 0.90. The overall precision of the delay estimates was 8-9 h. The delay between last heroin consumption and blood sampling in chronic drug users can be satisfactorily predicted from plasma heroin metabolites.

Для цитирования: Dubois Nathalie, Hallet Claude, Seidel Laurence, Demaret Isabelle, Luppens David, Ansseau Marc, Rozet Eric, Albert Adelin, Hubert Philippe, Charlier Corinne. Estimation of the Time Interval between the Administration of Heroin and the Sampling of Blood in Chronic Inhalers.. Journal of analytical toxicology. 2015. DOI: 10.1093/jat/bkv001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.