MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7507/1002-1892.202204073

Медицинская библиотека · Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2022

[Orthopedic robot based on 5G technology for remote navigation of percutaneous screw fixation in pelvic and acetabular fractures].

Zhao Bin, Li Jinqi, Zhao Chunpeng, Su Yonggang, Han Wei, Wu Xinbao, Jiang Xieyuan, Wang Junqiang

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the accuracy and safety of percutaneous screw fixation for pelvic and acetabular fractures with remote navigation of orthopedic robot based on 5G technology.

METHODS

Between January 2021 and December 2021, 15 patients with pelvic and/or acetabular fractures were treated with percutaneous screws fixation which were placed by remote navigation of orthopedic robot based on 5G technology. There were 8 males and 7 females. The age ranged from 20 to 98 years, with an average of 52.1 years. The causes of trauma included traffic accident injury in 6 cases, falling from height injury in 6 cases, fall injury in 2 cases, and heavy object smashing injury in 1 case. The time from injury to operation ranged from 3 to 32 days, with an average of 10.9 days. There were 8 cases of simple pelvic fractures, 2 simple acetabular fractures, and 5 both pelvic and acetabular fractures. There were 7 cases of pelvic fractures of Tile type B2, 2 type B3, 1 type C1, and 3 type C2; 4 cases of unilateral anterior column fracture of the acetabulum, 2 bilateral anterior column fractures, and 1 anterior wall fracture. CT images within 5 days after operation were collected for screw position assessment. The screw planning time and guidewire placement time were recorded, as well as the presence of intraoperative adverse events and complications within 5 days after operation.

RESULTS

All patients achieved satisfactory surgical results. A total of 36 percutaneous screws were inserted (20 sacroiliac screws, 6 LC Ⅱ screws, 9 anterior column screws, and 1 acetabular apical screw). In terms of screw position evaluation, 32 screws (88.89%) were excellent and 4 screws (11.11%) were good; there was no screw penetrating cortical bone. The screw planning time ranged from 4 to 15 minutes, with an average of 8.7 minutes. The guidewire placement time ranged from 3 to 10 minutes, with an average of 6.8 minutes. The communication delayed in 2 cases, but the operation progress was not affected, and no serious intraoperative adverse events occurred. No delayed vascular or nerve injury, infection, or other complications occurred within 5 days after operation. No cases need surgical revision.

CONCLUSION

The fixation of pelvic and acetabular fractures by percutaneous screw with remote navigation of orthopedic robot based on 5G technology is accurate, safe, and reliable.

Для цитирования: Zhao Bin, Li Jinqi, Zhao Chunpeng, Su Yonggang, Han Wei, Wu Xinbao, Jiang Xieyuan, Wang Junqiang. [Orthopedic robot based on 5G technology for remote navigation of percutaneous screw fixation in pelvic and acetabular fractures].. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. 2022. DOI: 10.7507/1002-1892.202204073.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.