MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.resuscitation.2007.04.007

Медицинская библиотека · Resuscitation · 2007

A simpler cardiac arrest model in the mouse.

Chen Meng-Hua, Liu Tang-Wei, Xie Lu, Song Feng-Qing, He Tao, Mo Shu-Rong, Zeng Zhi-Yu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Delivering alternating currency (AC) to right ventricular endocardium to induce ventricular fibrillation (VF) in mice is complicated. We tried to validate whether transoesophageal AC stimulation could induce VF and how long AC stimulation had to be sustained to prevent the spontaneous cardioversion of VF in mice.

METHODS

A pacing electrode was inserted orally into the oesophagus and AC was delivered to esophagus through the pacing electrode to stimulate the heart and induce VF in 15 mice. The incidence of VF and time of AC stimulation were recorded 4min after onset of VF cardiopulmonary resuscitation (CPR) was started.

RESULTS

VF was induced by short AC stimulation in all 15 mice. With the prolongation of AC stimulation, the incidences of spontaneous cardioversion of VF decreased whereas the incidence of pulseless electrical activity (PEA) increased accordingly. Following the termination of prolonged AC stimulation, VF occurred only in 1 of 15 mice, but PEA in 14 of 15 mice. Before CPR 1 of 15 and 12 of 15 animals remained in VF and in PEA, respectively, while 2 of 15 animals developed into asystole. After CPR, 11 of 15 animals were successfully resuscitated.

CONCLUSION

VF can be induced by a short period of transoesophageal AC stimulation in mice. However, prolonged AC stimulation is prone to induce PEA other than VF. Nonetheless, the development of a mouse CA model in this manner is simpler and easier, which may have practical significance for facilitating experimental investigation on CA and CPR.

Для цитирования: Chen Meng-Hua, Liu Tang-Wei, Xie Lu, Song Feng-Qing, He Tao, Mo Shu-Rong, Zeng Zhi-Yu. A simpler cardiac arrest model in the mouse.. Resuscitation. 2007. DOI: 10.1016/j.resuscitation.2007.04.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.