MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000026004

Медицинская библиотека · Medicine · 2021

Diagnostic accuracy of novel folate receptor-mediated staining solution detection (FRD) for CIN2+: A systematic review and meta analysis.

Li Yuan-Xing, Luo Hai-Xia, Wang Wei, Wang Zhe, Zhao Wei-Hong, Hao Min

Сравнительное исследованиеОценочное исследованиеСтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

Early detection and diagnosis of high-grade cervical intraepithelial neoplasia grade 2 or higher (CIN2+) is critical for a good prognosis and appropriate treatment. The chief aim of our study was to evaluate the diagnostic performance of folate receptor-mediated staining solution detection (FRD) for CIN2+.

METHODS

We conducted a systematic review and meta-analysis by searching the PubMed and EMBASE databases for studies published until May 2020, which assessed the diagnostic accuracy of FRD, human papilloma virus (HPV) testing, and ThinPrep cytology test (TCT) for the detection of CIN2+. Bivariate models were used to compare the diagnostic performance of FRD, HPV, and TCT.

RESULTS

Six studies involving 2817 patients were included in this meta-analysis. The pooled specificity of FRD was higher than that of HPV and TCT for detecting CIN2+ (0.65, 0.12, and 0.39, respectively). The summary area under the receiver operating characteristic curve values using FRD, HPV, and TCT for detecting CIN2+ were 0.79, 0.95, and 0.77, respectively, indicating that FRD was superior to TCT. The diagnostic odds ratios of FRD, HPV, and TCT were 6 (95% CI: 5-7), 3 (95% CI: 2-5), and 3 (95% CI: 2-4), respectively, demonstrating that FRD had good diagnostic accuracy.

CONCLUSION

FRD showed good diagnostic accuracy and higher specificity than HPV and TCT for detecting CIN2+. Based on our results, we propose that FRD could be a candidate for cervical screening, especially in underdeveloped countries.

Для цитирования: Li Yuan-Xing, Luo Hai-Xia, Wang Wei, Wang Zhe, Zhao Wei-Hong, Hao Min. Diagnostic accuracy of novel folate receptor-mediated staining solution detection (FRD) for CIN2+: A systematic review and meta analysis.. Medicine. 2021. DOI: 10.1097/md.0000000000026004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.