MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjci/jet065

Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2013

Evaluation of myocardial mechanics with three-dimensional speckle tracking echocardiography in heart transplant recipients: comparison with two-dimensional speckle tracking and relationship with clinical variables.

Urbano-Moral Jose Angel, Arias-Godinez Jose Antonio, Ahmad Raabia, Malik Rabiya, Kiernan Michael S, DeNofrio David, Pandian Natesa G, Patel Ayan R

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

AIMS: Two-dimensional speckle-tracking echocardiography (2D-STE) is limited by its inability to track tissue motion in three dimensions. This is particularly relevant in heart transplant recipients, in whom marked translational motion of the transplanted heart is present. We aimed to compare 3-dimensional (3D)- and 2D-STE-derived strain parameters, and to identify clinical features associated with myocardial mechanics in transplant recipients.

METHODS AND

RESULTS

In 36 heart transplant recipients, global and regional left-ventricular (LV) longitudinal and circumferential strain (LSt and CSt), and radial displacement (RDisp) were obtained by 3D- and 2D-STE, and their results were compared. 3D-STE deformation from a subset of transplant recipients with preserved ejection fraction was compared with a control group of 25 subjects matched by gender, age, history of hypertension, and ejection fraction. Associations between global LSt and CSt and clinical, echocardiographic, and haemodynamic parameters in transplant recipients were investigated. 3D-STE yielded lower magnitude of global LSt compared with 2D-STE (-13 ± 3 vs. -16 ± 3%, P < 0.001). The inferolateral wall was a source of variation between 3D- and 2D-STE both for LSt and CSt. Inferolateral wall 3D-STE-derived RDisp was greater than that observed in control subjects (7.4 ± 1.2 vs. 6.5 ± 1.7 mm, P = 0.03), while anteroseptal RDisp was lower than controls (4.2 ± 1.0 vs. 7.3 ± 1.6 mm, P < 0.001). Multiple regression analysis demonstrated that 3D-STE-derived LSt was independently associated with NYHA class (P < 0.001), while 2D-STE-derived LSt was not.

CONCLUSION

Examination of LV mechanics by 3D- and 2D-STE deformation parameters in heart transplant recipients yields significantly discordant results. 3D-STE-derived LSt is independently associated with NYHA class, suggesting a clinically important relationship between functional status and myocardial mechanics.

Для цитирования: Urbano-Moral Jose Angel, Arias-Godinez Jose Antonio, Ahmad Raabia, Malik Rabiya, Kiernan Michael S, DeNofrio David, Pandian Natesa G, Patel Ayan R. Evaluation of myocardial mechanics with three-dimensional speckle tracking echocardiography in heart transplant recipients: comparison with two-dimensional speckle tracking and relationship with clinical variables.. European heart journal. Cardiovascular Imaging. 2013. DOI: 10.1093/ehjci/jet065.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.