Insertion of durable left ventricular assist device with repair of ischemic ventricular septal rupture.

Hirani Rahim, Ohira Suguru, Spielvogel David, De La Pena Corazon, Kai Masashi

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

A 63-year-old male who presented with acute anterior wall myocardial infarction with ischemic ventricular septal defect (VSD) required veno-arterial extracorporeal membrane oxygenation support due to a profoundly reduced left ventricular function.

METHOD AND RESULS: The VSD was closed with a large bovine pericardial patches. Another Dacron patch was used to close the defect on the anterior wall. The inflow cannula of the left ventricular assist device (LVAD) was sewn to the Dacron patch to secure hemostasis and to maintain the cavity in the left ventricle. The Dacron patch beneath the inflow cuff was then incised, then the LVAD was connected.

CONCLUSIONS

we described a case of concomitant insertion of durable LVAD and repair of ischemic VSD utilizing multiple patches.

Для цитирования: Hirani Rahim, Ohira Suguru, Spielvogel David, De La Pena Corazon, Kai Masashi. Insertion of durable left ventricular assist device with repair of ischemic ventricular septal rupture.. Journal of cardiac surgery. 2022. DOI: 10.1111/jocs.16952.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.