MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-012-2644-6

Медицинская библиотека · European radiology · 2012

Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance.

Choo Ji Yung, Park Chang Min, Lee Nyoung Keun, Lee Sang Min, Lee Hyun-Ju, Goo Jin Mo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To describe our initial experience with percutaneous transthoracic needle biopsy (PCNB) of small (≤1 cm) lung nodules using a cone-beam computed tomography (CBCT) virtual navigation guidance system in 105 consecutive patients.

METHODS

One hundred and five consecutive patients (55 male, 50 female; mean age, 62 years) with 107 small (≤1 cm) lung nodules (mean size, 0.85 cm ± 0.14) underwent PCNBs under CBCT virtual-navigation guidance system and constituted our study population. Procedural details-including radiation dose, sensitivity, specificity, diagnostic accuracy and complication rates of CBCT virtual navigation guided PCNBs-were described.

RESULTS

The mean number of pleural passages with the coaxial needle, biopsies, CT acquisitions, total procedure time, coaxial introducer dwelling time, and estimated radiation exposure during PCNBs were 1.03 ± 0.21, 3.1 ± 0.7, 3.4 ± 1.3, 10.5 min ± 3.2 and 7.2 min ± 2.5, and 5.72 mSv ± 4.19, respectively. Sixty nodules (56.1 %) were diagnosed as malignant, 38 (35.5 %) as benign and nine (8.4 %) as indeterminate. The sensitivity, specificity, and diagnostic accuracy of CBCT virtual-navigation-guided PCNB for small (≤1 cm) nodules were 96.7 % (58/60), 100 % (38/38) and 98.0 % (96/98), respectively. Complications occurred in 13 (12.1 %) cases; pneumothorax in seven (6.5 %) and haemoptysis in six (5.6 %).

CONCLUSION

CBCT virtual-navigation-guided PCNB is a highly accurate and safe diagnostic method for small (≤1 cm) nodules.

Для цитирования: Choo Ji Yung, Park Chang Min, Lee Nyoung Keun, Lee Sang Min, Lee Hyun-Ju, Goo Jin Mo. Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance.. European radiology. 2012. DOI: 10.1007/s00330-012-2644-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.