Robotically assisted mitral valve replacement.

Gao Changqing, Yang Ming, Xiao Cangsong, Wang Gang, Wu Yang, Wang Jiali, Li Jiachun

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

In the present study, we determined the safety and efficacy of robotic mitral valve replacement using robotic technology.

METHODS

From January 2007 through March 2011, more than 400 patients underwent various types of robotic cardiac surgery in our department. Of these, 22 consecutive patients underwent robotically assisted mitral valve replacement. Of the 22 patients with isolated rheumatic mitral valve stenosis (9 men and 13 women), the mean age was 44.7 ± 19.8 years (range, 32-65). Preoperatively, all patients underwent a complete workup, including coronary angiography and transthoracic echocardiography. Of the 22 patients, 15 had concomitant atrial fibrillation. The surgical approach was through 4 right-side chest ports with femoral perfusion. Aortic occlusion was performed with a Chitwood crossclamp, and antegrade cardioplegia was administered directly by way of the anterior chest. Using 3 port incisions in the right side of the chest and a 2.5- to 3.0-cm working port, all the procedures were completed with the da Vinci S robot.

RESULTS

All patients underwent successful robotic surgery. Of the 22 patients, 16 received a mechanical valve and 6 a tissue valve. The mean cardiopulmonary bypass time and aortic crossclamp time was 137.1 ± 21.9 minutes (range, 105-168) and 99.3 ± 17.9 minutes (range, 80-133), respectively. No operative deaths, stroke, or other complications occurred, and no incisional conversions were required. After surgery, all the patients were followed up echocardiographically.

CONCLUSIONS

Robotically assisted mitral valve replacement can be performed safely in patients with isolated mitral valve stenosis, and surgical results are excellent.

Для цитирования: Gao Changqing, Yang Ming, Xiao Cangsong, Wang Gang, Wu Yang, Wang Jiali, Li Jiachun. Robotically assisted mitral valve replacement.. The Journal of thoracic and cardiovascular surgery. 2012. DOI: 10.1016/j.jtcvs.2012.01.045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.