MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13023-023-02766-7

Медицинская библиотека · Orphanet journal of rare diseases · 2023

Blunted circadian variation of blood pressure in individuals with neurofibromatosis type 1.

Rivera Ana M Cieza, Fernández-Villa Tania, Martín Vicente, Atallah Isis

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Cardiovascular events such as myocardial infarction and stroke are life-threatening complications associated with Neurofibromatosis type 1 (NF1). As previous studies observed an association between cardiovascular events and the loss of circadian variations of blood pressure, we investigated the 24 h circadian rhythm of blood pressure (BP) in 24 NF1 patients (10 males and 14 females, with a mean age of 39.5 years ± 14 years) by using ambulatory blood pressure monitoring (ABPM).

RESULTS

Only one-third of the patient were dippers, 50% were non-dippers, and 17% were risers. Reduced variability of systolic and diastolic nocturnal blood pressure was observed in NF1 patients compared with several studies of normotensive individuals (p = 0.024). In NF1 patients, the blunted systolic nocturnal decline was significantly associated with the number of neurofibromas (p = 0.049) and the presence of a plexiform neurofibroma (p = 0.020).

CONCLUSIONS

Most NF1 patients in this study showed a "non-dipper" pattern with a blunted nocturnal BP decline, which is considered an independent risk factor for cardiovascular events in normotensive and hypertensive individuals. Periodic monitoring of BP should be included in NF1 follow-up guidelines to diagnose masked hypertension or a non-dipper/riser pattern which would significantly increase the morbidity and mortality of NF1 patients to implement therapeutic strategies.

Для цитирования: Rivera Ana M Cieza, Fernández-Villa Tania, Martín Vicente, Atallah Isis. Blunted circadian variation of blood pressure in individuals with neurofibromatosis type 1.. Orphanet journal of rare diseases. 2023. DOI: 10.1186/s13023-023-02766-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.