Journal of the American Veterinary Medical Association · 1999
Comparison of a continuous suture pattern with a simple interrupted pattern for enteric closure in dogs and cats: 83 cases (1991-1997).
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Weisman D L, Smeak D D, Birchard S J, Zweigart S L
Аннотация
OBJECTIVE: To describe and compare a simple continuous suture pattern with a simple interrupted pattern for enterotomy closure or end-to-end intestinal anastomosis.
DESIGN: Retrospective study.
ANIMALS: 58 dogs and 25 cats that underwent enterotomy or intestinal resection and anastomosis.
PROCEDURE: Signalment, surgical procedure, suture pattern, suture material, confirmation of dehiscence, and follow-up were reviewed. Groups were compared by procedure (anastomosis or enterotomy) and by suture pattern.
RESULTS: 57 animals underwent continuous closure; 26 had interrupted closure. Only polydioxanone or polypropylene suture materials were used. Overall, 81 (98%) animals had no signs of intestinal dehiscence and survived > 2 weeks. Two animals had confirmed dehiscence after foreign body removal, 1 of 57 (2%) after continuous closure, and 1 of 26 (4%) after interrupted closure.
CLINICAL IMPLICATIONS: The simple continuous closure pattern is an acceptable alternative to simple interrupted closure for small intestinal anastomosis or enterotomy closure.
DESIGN: Retrospective study.
ANIMALS: 58 dogs and 25 cats that underwent enterotomy or intestinal resection and anastomosis.
PROCEDURE: Signalment, surgical procedure, suture pattern, suture material, confirmation of dehiscence, and follow-up were reviewed. Groups were compared by procedure (anastomosis or enterotomy) and by suture pattern.
RESULTS: 57 animals underwent continuous closure; 26 had interrupted closure. Only polydioxanone or polypropylene suture materials were used. Overall, 81 (98%) animals had no signs of intestinal dehiscence and survived > 2 weeks. Two animals had confirmed dehiscence after foreign body removal, 1 of 57 (2%) after continuous closure, and 1 of 26 (4%) after interrupted closure.
CLINICAL IMPLICATIONS: The simple continuous closure pattern is an acceptable alternative to simple interrupted closure for small intestinal anastomosis or enterotomy closure.