MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13065-026-01765-6

Медицинская библиотека · BMC chemistry · 2026

High-performance thin-layer chromatographic method for simultaneous determination of some Angiotensin II Receptor Antagonists with amlodipine in spiked human plasma with UV detection.

Khorshed Ahmed A, Abdelnaeem Fatma M, Nagy Dalia M, Oraby Mohamed, Derayea Sayed M

СтатьяПеревод в очереди

Аннотация

A simple, sensitive, precise, and cost-effective high-performance thin-layer chromatographic method has been developed and validated for the simultaneous determination of Amlodipine and some Angiotensin II Receptor Antagonist drugs, including Olmesartan, Telmisartan, Candesartan, Losartan, and Irbesartan, in spiked human plasma. The HPTLC analysis utilized a mobile phase consisting of toluene: ethyl acetate: methanol: acetone: acetic acid (6:1.5:1:0.5:1, v/v/v/v/v) on an aluminum-backed layer of silica gel 60 F254. Amlodipine demonstrated a linear relationship within the range of 60-600 ng/band, while the AIIRA drugs showed linearity within the range of 90-900 ng/band. The proposed method exhibited good linearity, with correlation coefficients (r) ranging from 0.9939 to 0.9998 for all five studied mixtures. The method was validated according to International Council for Harmonization guidelines for linearity, accuracy, precision, robustness, and detection and quantitation limits. Amlodipine and the investigated Angiotensin II Receptor Antagonist drugs were successfully detected and quantified in both bulk drug and plasma samples, yielding high recovery percentages and low standard deviation values. The greenness of the proposed HPTLC method has been evaluated using the standards of greenness profile (AGREE and GAPI) and Eco-Scale.

Для цитирования: Khorshed Ahmed A, Abdelnaeem Fatma M, Nagy Dalia M, Oraby Mohamed, Derayea Sayed M. High-performance thin-layer chromatographic method for simultaneous determination of some Angiotensin II Receptor Antagonists with amlodipine in spiked human plasma with UV detection.. BMC chemistry. 2026. DOI: 10.1186/s13065-026-01765-6.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.