DOI 10.1186/s13019-023-02335-w
Retrospective single-arm cohort study of video-assisted thoracic surgery for treatment of idiopathic peripherally located simple type pulmonary arteriovenous malformation in 23 consecutive patients.
Аннотация
BACKGROUND
Although case reports of video-assisted thoracic surgery (VATS) for pulmonary arteriovenous malformation (PAVM) have been published, studies analyzing more than 10 cases were limited. A retrospective single-arm cohort study was performed to investigate the efficacy of VATS in 23 consecutive patients with idiopathic peripherally located simple type PAVM.
METHODS
VATS was performed for wedge resection of 24 PAVMs in 23 patients, which included 4 males and 19 females with an age range of 25 to 80 years (mean: 59.6 ± 13.0). Two patients underwent simultaneous resection of lung carcinoma, one by wedge resection and another by lobectomy. Each medical record was analyzed according to the resected specimen, bleeding volume, postsurgical hospital stay length, duration of chest tube placement, and VATS time. The distance between pleural surface/fissure and PAVM was measured on CT, and the influence of this distance on identification of PAVM was investigated.
RESULTS
In all 23 patients, VATS was successfully performed, and the venous sac was included in each resected specimen. Bleeding volume was less than 10mL in all but one with 1900 mL bleeding volume due to simultaneous lobectomy for carcinoma, not wedge resection of PAVM. Postsurgical hospital stay length, duration of chest tube placement, and VATS time were 5.0 ± 1.4 days, 2.7 ± 0.7 days, and 49.3 ± 39.9 min, respectively. In 21 PAVMs with a distance of 1 mm or less, purple vessel or pleural bulge of PAVM was identified soon after insertion of a thoracoscope. In the remaining 3 PAVMs with a distance of 2.5 mm or more, additional efforts were needed for identification.
CONCLUSION
VATS was found to be a safe and effective to treatment for idiopathic peripherally located simple type PAVM. When the distance between pleural surface/fissure and PAVM was 2.5 mm or more, a plan and strategy for identification of PAVM should be prepared before VATS.