DOI 10.1097/00006123-200202000-00039
C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note.
Аннотация
OBJECTIVE AND
IMPORTANCE
Transarticular screw fixation of the C1-C2 complex provides immediate rigid fixation of the unstable spine. The technique is not feasible in a certain proportion of patients because of the position of the vertebral artery or the patient's body habitus.
CLINICAL PRESENTATION: The authors describe a rigid screw technique for the surgical treatment of a woman who was excluded as a candidate for C1-C2 transarticular screw fixation.
TECHNIQUE: C1-C2 pedicle screw fixation was achieved using a fixed moment arm cantilever beam system. This system provided immediate rigid fixation of the C1-C2 complex in a patient who was not a candidate for transarticular screw fixation.
CONCLUSION
This technique is technically more forgiving than posterior transarticular screw fixation and may be applied to a broader spectrum of patients.