OBJECTIVE

This study aimed to examine whether, on the basis of the relationship between sensors attached on the upper limbs and energy expenditure (EE) at the time of wheelchair propulsion, there are differences in the measurement of EE depending on the sensor attachment site and whether addition of the angular velocity information to the acceleration value is advantageous. We also aimed to clarify the variables used to estimate EE as well as the estimated error.

SETTING

Laboratory of the National Hospital Organization Murayama Medical Center, Japan.

METHODS

Six male subjects with spinal cord injuries participated in the study. Each wore sensors at the wrist and the middle upper arm on both sides while driving a wheelchair on a treadmill at three levels: very, very light; very light; and fairly light. Triaxial acceleration, triaxial angular velocity and EE were measured during driving. We analyzed the correlation between EE and acceleration, angular velocity and synthesized values of acceleration and angular velocity at each location using regression, multiple regression and Bland-Altman analyses.

RESULTS

The determination coefficients between EE and the acceleration, angular velocity and synthesized values of acceleration and angular velocity varied from 0.68 to 0.87 at each location. The mean difference between the measured and estimated EE varied from 0.0028 (s.d., 0.0027) kcal min(-1) kg(-1) on the right upper arm.

CONCLUSION

These findings suggest that combining the synthesized values of angular velocity and acceleration of the motion sensors on the upper limbs might reflect EE during a wheelchair driving activity on a treadmill.

Для цитирования: Kiuchi K, Inayama T, Muraoka Y, Ikemoto S, Uemura O, Mizuno K. Preliminary study for the assessment of physical activity using a triaxial accelerometer with a gyro sensor on the upper limbs of subjects with paraplegia driving a wheelchair on a treadmill.. Spinal cord. 2014. DOI: 10.1038/sc.2014.70.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.