PURPOSE: Intraoperative neural monitoring (IONM) technology was applied in minimally invasive video-assisted thyroidectomy (MIVAT) to explore its safety and effectiveness.

MATERIALS AND

METHODS

Data were collected retrospectively from October 2009 to August 2011. Inclusion criteria included the following: (1) benign thyroid nodule with maximum diameter less than 4.0 cm by preoperative ultrasound evaluation; (2) no previous thyroid surgeries; (3) no cervical radiation history; (4) normal function of recurrent laryngeal nerve (RLN) examined by preoperative laryngoscopy; (5) patients who did not accept to take a "wait and see" follow-up strategy. Enrolled patients were randomly allocated into NIM group and control group.

RESULTS

46 patients were enrolled in NIM group, and 51 patients were enrolled in control group. All surgeries in NIM group were performed successfully, and majority of tracheal intubations were placed with one attempt. 47 RLNs in NIM group and 60 RLNs in control group were exposed. The time of RLN locating was 6.06 ± 1.48 min in NIM group and 6.92 ± 1.34 min in control group (p = .02). The time of RLN tracing and exposing was 28.96 ± 4.75 min in NIM group and 32.17 ± 5.56 min in control group (p = .02). 1 case of temporary RLN paralysis was observed in both groups, and no permanent RLN paralysis was reported.

CONCLUSIONS

The application of intermittent IONM in MIVAT is feasible. Intermittent IONM can help reduce the time of RLN locating and the time of RLN tracing and exposing.

Для цитирования: Hei Hu, Zhai Yifei, Qin Jianwu, Song Yongping. Intermittent Intraoperative Neural Monitoring Technology in Minimally Invasive Video-Assisted Thyroidectomy: A Preliminary Study.. Journal of investigative surgery : the official journal of the Academy of Surgical Research. 2016. DOI: 10.3109/08941939.2015.1073411.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.