MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0018720812469046

Медицинская библиотека · Human factors · 2013

Frequency characteristics of visually induced motion sickness.

Diels Cyriel, Howarth Peter A

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to explore the frequency response of visually induced motion sickness (VIMS) for oscillating linear motion in the fore-and-aft axis.

BACKGROUND

Simulators, virtual environments, and commercially available video games that create an illusion of self-motion are often reported to induce the symptoms seen in response to true motion. Often this human response can be the limiting factor in the acceptability and usability of such systems. Whereas motion sickness in physically moving environments is known to peak at an oscillation frequency around 0.2 Hz, it has recently been suggested that VIMS peaks at around 0.06 Hz following the proposal that the summed response of the visual and vestibular self-motion systems is maximized at this frequency.

METHODS

We exposed 24 participants to random dot optical flow patterns simulating oscillating fore-and-aft motion within the frequency range of 0.025 to 1.6 Hz. Before and after each 20-min exposure, VIMS was assessed with the Simulator Sickness Questionnaire. Also, a standard motion sickness scale was used to rate symptoms at 1-min intervals during each trial.

RESULTS

VIMS peaked between 0.2 and 0.4 Hz with a reducing effect at lower and higher frequencies.

CONCLUSION

The numerical prediction of the "crossover frequency" hypothesis, and the design guidance curve previously proposed, cannot be accepted when the symptoms are purely visually induced.

APPLICATION: In conditions in which stationary observers are exposed to optical flow that simulates oscillating fore-and-aft motion, frequencies around 0.2 to 0.4 Hz should be avoided.

Для цитирования: Diels Cyriel, Howarth Peter A. Frequency characteristics of visually induced motion sickness.. Human factors. 2013. DOI: 10.1177/0018720812469046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.