MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00256-017-2810-7

Медицинская библиотека · Skeletal radiology · 2017

Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs: an accuracy and feasibility study.

Hakimian David, Khoury Amal, Mosheiff Rami, Liebergall Meir, Weil Yoram A

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile.

METHODS

The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA© software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy.

RESULTS

Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar.

CONCLUSIONS

To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft.

Для цитирования: Hakimian David, Khoury Amal, Mosheiff Rami, Liebergall Meir, Weil Yoram A. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs: an accuracy and feasibility study.. Skeletal radiology. 2017. DOI: 10.1007/s00256-017-2810-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.