MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2020.121487

Медицинская библиотека · Talanta · 2020

Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum.

Aydın Elif Burcu, Aydın Muhammet, Sezgintürk Mustafa Kemal

СтатьяПеревод в очереди

Аннотация

This study described the first impedimetric immunosensor reported for the determination of CCR4, a new prostate cancer biomarker. This impedimetric immunosensor was constructed through the modification of disposable indium tin oxide (ITO) sheet with a conjugated pyrrole polymer P(Pyr-Pac) and subsequent immobilization of anti-CC chemokine receptor 4 (CCR4) antibodies. Acid-substituted poly(pyrrole) P(Pyr-Pac) polymer contained a lot of carboxyl groups on its end site, which were suitable for attachment of anti-CCR4 antibodies. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were chosen to investigate electrode preparation stages and, EIS was chosen to detect the CCR4 concentration. Anti-CCR4 antibody attached biosensing surface was highly selective to CCR4 antigen, the specific interaction resulted changes in electrochemical signal. Optimization studies containing polymer amount, anti-CCR4 antibody concentration, anti-CCR4 antibody immobilization time and anti-CCR4 antibody-CCR4 antigen interaction time were studied. The developed immunosensor displayed a linear increase with concentrations of CCR4 antigen (0.02-8 pg/mL) and a low detection limit of 6.4 fg/mL. In addition, this biosensor had great reproducibility and repeatability. Moreover, the designed biosensor was successfully used for the quantification of CCR4 antigen in serum samples. The recovery for the spiked serum samples was between 98.25% and 103.99%. The suggested immunosensor illustrated a good selectivity towards some interferents including different biomarkers. This study could establish a new approach for future cancer biomarker detection.

Для цитирования: Aydın Elif Burcu, Aydın Muhammet, Sezgintürk Mustafa Kemal. Fabrication of electrochemical immunosensor based on acid-substituted poly(pyrrole) polymer modified disposable ITO electrode for sensitive detection of CCR4 cancer biomarker in human serum.. Talanta. 2020. DOI: 10.1016/j.talanta.2020.121487.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.