MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr/24730002

Медицинская библиотека · The British journal of radiology · 2012

64-detector row CT evaluation of bronchial and non-bronchial systemic arteries in life-threatening haemoptysis.

Ponnuswamy I, Sankaravadivelu S T, Maduraimuthu P, Natarajan K, Sathyanathan B P, Sadras S

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To retrospectively evaluate the depiction of bronchial and non-bronchial systemic arteries with 64-detector row CT in patients undergoing endovascular treatment for life-threatening haemoptysis.

METHODS

64-detector row helical CT and conventional angiography of the thorax were performed in 28 patients (25 males, 3 females; age range, 18-65 years; mean age, 40 years) with life-threatening haemoptysis. CT images were analysed to identify abnormal bronchial and non-bronchial systemic arteries and also to localise them in two planes.

RESULTS

Using multidetector CT (MDCT), 43 bronchial arteries were identified on the right side and 46 on the left side. 89% of the right bronchial arteries originated from the right intercostobronchial arteries. A common trunk of origin of the right and left bronchial artery was noted in 46% of cases. 23 non-bronchial systemic arteries were noted on the right side and 41 on the left side. Pleural thickening >3 mm was confirmed to be a good predictor of non-bronchial systemic supply. An internal mammary artery diameter of >3 mm and an inferior phrenic artery diameter of >2 mm were sensitive indicators for non-bronchial systemic supply.

CONCLUSION

MDCT is a good investigation tool for evaluating life-threatening haemoptysis as it confirms the disease process, identifies the origin and ostial position of bronchial arteries, detects non-bronchial systemic arteries and acts as a roadmap for percutaneous transcatheter embolisation.

Для цитирования: Ponnuswamy I, Sankaravadivelu S T, Maduraimuthu P, Natarajan K, Sathyanathan B P, Sadras S. 64-detector row CT evaluation of bronchial and non-bronchial systemic arteries in life-threatening haemoptysis.. The British journal of radiology. 2012. DOI: 10.1259/bjr/24730002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.