DOI 10.1016/j.jaapos.2016.01.017
Colorado retinopathy of prematurity model: a multi-institutional validation study.
Аннотация
PURPOSE: The Colorado retinopathy of prematurity (ROP) prediction model (CO-ROP), developed using a cohort of infants from Colorado, calls for ROP examination of infants meeting all of the following criteria: gestational age of ≤30 weeks, birth weight of ≤1500 g, and a net weight gain of ≤650 g between birth and 4 weeks of age. The purpose of this study was to perform an external validation to assess the sensitivity and specificity of the CO-ROP model in a larger cohort of babies screened for ROP from four academic institutions in the United States.
METHODS
The medical records of neonates screened for ROP according current national guidelines was conducted at 4 US academic centers were retrospectively reviewed. Sensitivity, specificity, and respective 95% confidence intervals in detecting ROP using CO-ROP were calculated for type 1, type 2, and any grade of ROP.
RESULTS
A total of 858 cases were included. The CO-ROP algorithm had a sensitivity of 98.1% (95% CI, 93.3%-99.8%) for type 1 ROP, 95.6% (95% CI 78.0-99.9%) for type 2 ROP, and 95.0% (95% CI, 93.1-97.4%) for all grades of ROP. The CO-ROP model would have reduced the total number of infants screened by 23.9% compared to current 2013 screening guidelines.
CONCLUSIONS
CO-ROP demonstrated high sensitivity in predicting ROP and would have greatly reduced the number of infants needing examination.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.