DOI 10.1148/radiology.219.3.r01jn09811
Radial nerve palsy associated with humeral shaft fracture: evaluation with US--initial experience.
Аннотация
PURPOSE: To determine the feasibility of using ultrasonography (US) for evaluation of a radial nerve injury associated with humeral shaft fracture.
MATERIALS AND
METHODS
In a prospective study, 11 consecutive patients with sensorimotor radial deficiency after distal humeral fracture were evaluated with conventional radiography, US, electroneurography, and electromyography. Surgical repair of the fracture and nerve inspection were performed in five patients. The remaining six patients were successfully treated conservatively. The US appearance of the radial nerve was studied in 10 healthy volunteers and in the noninjured arm of the 11 patients for comparison.
RESULTS
In five patients, US findings of a severely damaged radial nerve were confirmed at surgical nerve inspection. In one patient, the nerve was entrapped between fragments. One patient had a complete nerve dissection, one had a lacerated nerve from a loose compression plate, and one had a nerve riding on the edge of a bone fragment. In the fifth patient who underwent surgical inspection, the nerve was buried in the callus. In the six patients treated conservatively, US showed continuity of the nerve.
CONCLUSION
US may be useful for accurate evaluation of the radial nerve in patients with nerve palsy associated with humeral shaft fracture.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.