MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1010-7940(02)00062-3

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2002

Acute traumatic aortic rupture: early stent-graft repair.

Lachat M, Pfammatter T, Witzke H, Bernard E, Wolfensberger U, Künzli A, Turina M

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Prospective evaluation of early stent-graft repair of acute traumatic aortic rupture.

METHODS

Twelve patients with acute traumatic aortic rupture of the descending aorta, out of a series of 337 endovascular aortic procedures, were treated by implantation of self-expanding stent-grafts. The procedures were performed within a mean post-injury time-period of 5+/-7 days (median: 1 day). The feasibility of stent-grafting was assessed by CT scanning and echography. Implantation was performed under local (n=6), or general anesthesia (n=6) if patients were already intubated (n=5) or required a common iliac artery access (n=1).

RESULTS

The immediate technical success rate was 100%. There were no post-procedure complications in all but one patient, who died 12 h postoperatively (8% mortality). Complete sealing of the aortic rupture in the remaining 11 patients was confirmed by postoperative CT scans. There were no intervention-related morbidity or mortality during the mean follow-up of 17 months. One patient with peri-graft leakage was successfully repaired with an additional stent-graft 12 months postoperatively.

CONCLUSION

Non-delayed or early stent-grafting in acute traumatic rupture of the descending aorta is feasible. This technique seems to be a valuable option, in particular when associated lesions may interfere with the surgical outcome. Immediate post-procedural CT scanning and/or echography should be performed, in order to rule out residual leakage.

Для цитирования: Lachat M, Pfammatter T, Witzke H, Bernard E, Wolfensberger U, Künzli A, Turina M. Acute traumatic aortic rupture: early stent-graft repair.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2002. DOI: 10.1016/s1010-7940(02)00062-3.