DOI 10.1016/j.ejogrb.2018.03.021
Implementation of the RCOG guidelines for prevention of obstetric anal sphincter injuries (OASIS) at two London Hospitals: A time series analysis.
Аннотация
OBJECTIVE
To audit the impact of implementation of the RCOG guidelines for prevention of Obstetric anal sphincter injuries (OASIS) by introducing antenatal perineal massage, manual perineal protection, and cutting episiotomies at 60° to the midline at the time of crowning.
DESIGN
Time series analysis; Setting - Two London teaching hospitals; Royal Free London (RFL) and Barnet; Population or Sample - All nulliparous women undergoing vaginal birth; Methods - Training was provided for above techniques. EPISCISSORS-60 were introduced to perform 60° episiotomies. Data were extracted from maternity databases and dashboards; Main Outcome Measures - OASIS rates before and after implementation.
RESULTS
Data from 2566 births were analysed. In operative vaginal deliveries (OVD), OASIS declined from 9.6% to 2% (p = 0.001) at Barnet and from 5.6% to 4.2% (p = 0.4) at RFL. OASIS reduced in nulliparous OVD's given episiotomies from 6.3% in the 'before' period to 0.6% in the 'after' period [p = 0.01] at Barnet. Before introduction of the EPISCISSORS-60, OASIS rate was 6.3% with episiotomies and 30% without episiotomies (p = 0.000). After introduction of the EPISCISSORS-60, OASIS rate was 0.63% with episiotomies v 16% without episiotomies (p = 0.000) at Barnet. At RFL, OASIS rate was 2.6% with episiotomies, and 42% without episiotomy (p = 0.000). In SVD's at Barnet, OASIS declined from 6.6% before to 0% after (p = 0.000) in women given episiotomies while it declined from 5.4% to 3% (p = 0.12) in those not given episiotomies. After introduction of the EPISCISSORS-60, OASIS was 0% in women with episiotomies and 3% in those without episiotomies (p = 0.04). In SVD's at RFL, OASIS was 0% in women given episiotomy v 4.7% without episiotomy (p = 0.03).
CONCLUSIONS
Deliveries with EPISCISSORS-60 episiotomies had lesser OASIS than those without episiotomies in both nulliparous OVD's and SVD's. OASIS was lower with EPISCISSORS-60 episiotomies than those with eyeballed episiotomies.