OBJECTIVE
Open surgical approaches to treat tibial avulsion fractures of the posterior cruciate ligament (PCL) often use large incisions involving extensive muscle dissection and retraction. The objective of this study was to describe a new mini-invasive approach targeting the fractured zone, to minimize surgical dissection and improve recovery and rehabilitation.
METHODS
The new approach was used in 15 males and seven females with isolated PCL avulsions. The length of the surgical incision, surgical time, need for conversion to open technique, visual analog scores (VAS) and duration of hospital stay were studied to assess the efficacy, learning curve and advantages of the new technique. Neurovascular complications were recorded. At the two-year follow-up, International Knee Documentation Committee (IKDC) scores were recorded to assess function.
RESULTS
Patients were followed up for a mean of 29months (range: 34-41). The mean length of the incision was 4.1cm (range: 3.4 to five) measured at the end of the procedure. None of the patients required conversion to an open technique and no neurovascular complications were recorded. The mean surgical time was 40min (range: 25-50). The mean VAS on discharge was 2.2 (range: one to four) and patients stayed at the hospital for a mean of 2.2days (range: one to three). The mean IKDC score at one-year post surgery was 86.4 (range: 83.9-90.8).
CONCLUSIONS
The new mini-invasive targeted approach provides adequate exposure for performing internal fixation of PCL avulsion fractures without the surgical morbidity associated with conventional open surgical approaches. The procedure is safe, fast and does not require a long learning curve.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.