Post hoc estimation of a quantitative restriction spectrum imaging biomarker for prostate cancer detection using conventional MRI.
Аннотация
BACKGROUND
Multiparametric MRI is useful for early detection of clinically significant prostate cancer (csPCa), but its standard apparent diffusion coefficient (ADC) has limited utility as a quantitative metric for automated, patient-level detection of csPCa. Restriction spectrum imaging (RSI), an advanced diffusion technique, yields a quantitative biomarker (RSIrs) that improves csPCa detection. RSIrs is typically calculated from a dedicated multi-b-value acquisition. RSIrs estimated from conventional MRI has not been studied.
PURPOSE: To evaluate the accuracy and validity of RSI metrics estimated post hoc from conventional diffusion-weighted imaging (DWI) to serve as a viable surrogate for a dedicated RSI acquisition.
MATERIALS AND
METHODS
We conducted a retrospective, multicenter study of patients with both a dedicated RSI acquisition and conventional DWI. We compared three different RSI restriction score (RSIrs) calculation methods: from the dedicated acquisition (RSIrsdedicated), from conventional DWI alone (RSIrspost-hoc), and from a combination of conventional DWI with only the high b-values from the RSI acquisition (RSIrscombo). We compared these methods for quantitative agreement and csPCa detection performance (area under the receiver operating characteristic [AUC, 95% confidence interval]) of maximum RSIrs (RSIrsmax) in the prostate compared to that of minimum ADC (ADC).
RESULTS
Data from n = 1095 patients (16 centers) were analyzed. Post hoc RSIrsmax differed systematically from RSIrsdedicated by a median of +156 (RSIrspost-hoc) and -59 (RSIrscombo), respectively. AUCs for csPCa detection were 0.51 [0.47,0.54], 0.60 [0.57,0.64], 0.70 [0.67,0.74], and 0.77 [0.74,0.80] for ADC, RSIrspost-hoc, RSIrscombo, and RSIrsdedicated, respectively.
CONCLUSION
Even when estimated using conventional DWI, RSIrs is a superior quantitative biomarker to ADC for automated, patient-level detection of csPCa. A dedicated RSI acquisition gives the best performance. A compromise would be to acquire high b-values (1500 and 2500 s/mm2) to complement low b-values (<1000 s/mm2) from conventional DWI.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.