SfM-3DULC: Reliability of a new 3D wound measurement procedure and its accuracy in projected area.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sánchez-Jiménez David, Buchón-Moragues Fernando F, Escutia-Muñoz Begoña, Botella-Estrada Rafael

Аннотация

Three-dimensional (3D) wound measurement lacks a gold standard to test accuracy. It is useful to develop procedures to scan wounds and reconstruct their 3D model with low-cost techniques. We present a new procedure (Structure from Motion [SfM]-3DULC) that uses photographs for measuring nine wound variables. We also propose a new variant of ImageJ in which an orthophoto is used to measure the projected area (Ortho-ImageJ). In addition, we compare the wound measurements made by dermatologists and non-experts. A group of five experts in dermatology and five non-specialists measured 33 leg wounds five times per procedure. Intra-rater and inter-rater reliability scores of SfM-3DULC were evaluated with the intraclass correlation coefficient (ICC 2,1). The accuracy of the two new procedures (SfM-3DULC and Ortho-ImageJ) in the measurement of projected area was assessed by comparing their values with those obtained using ImageJ, with the Wilcoxon matched-pairs signed rank test (α = 0.05). This test was also used to analyse the differences between the measurements made by dermatologists and non-experts. All the variables measured by dermatologists using SfM-3DULC showed excellent scores of intra-rater reliability (ICC > 0.99) and inter-rater reliability (ICC > 0.98). No significant differences between the three procedures were found when comparing their projected area values. Significant differences between the measurements of dermatologists and non-experts were found in most of the variables: circularity coefficient, perimeter, projected area, surface area, and reference surface area. The wound measurement procedure SfM-3DULC has an excellent reliability, is accurate for the measurement of projected area, and can be used by dermatologists for wound monitoring in everyday clinical practice.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты