MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bios15030174

Медицинская библиотека · Biosensors · 2025

Development of a Rapid-Response Fluorescent Probe for H2S: Mechanism Elucidation and Biological Applications.

Dvorak Trevor, Hernandez-Sandoval Haley, Cheku Sunayn, Mora Valencia González Marijose, Borer Linus, Grieser Riley, Carlson Kimberly A, Cao Haishi

СтатьяПеревод в очереди

Аннотация

Hydrogen sulfide (H2S) is an important signaling molecule involved in various physiological and pathological processes, making its accurate detection in biological systems highly desirable. In this study, two fluorescent probes (M1 and M2) based on 1,8-naphthalimide were developed for H2S detection via a nucleophilic aromatic substitution. M1 demonstrated high sensitivity and selectivity for H2S in aqueous media, with a detection limit of 0.64 µM and a strong linear fluorescence response in the range of 0-22 µM of NaHS. The reaction kinetics revealed a rapid response, with a reaction rate constant of 7.56 × 102 M-1 s-1, and M1 was most effective in the pH range of 6-10. Mechanism studies using 1H NMR titration confirmed the formation of 4-hydroxyphenyl-1,8-naphthalimide as the product of H2S-triggered nucleophilic substitution. M1 was applied in MDA-MB-231 cells for cell imaging, in which M1 provided significant fluorescence enhancement upon NaHS treatment, confirming its applicability for detecting H2S in biological environments. In comparison, M2, designed with extended conjugation for red-shifted emission, exhibited weaker sensitivity due to the reduced stability of its naphtholate product and lower solubility. These results demonstrate that M1 is a highly effective and selective fluorescent probe for detecting H2S, providing a valuable resource for investigating the biological roles of H2S in health and disease.

Для цитирования: Dvorak Trevor, Hernandez-Sandoval Haley, Cheku Sunayn, Mora Valencia González Marijose, Borer Linus, Grieser Riley, Carlson Kimberly A, Cao Haishi. Development of a Rapid-Response Fluorescent Probe for H2S: Mechanism Elucidation and Biological Applications.. Biosensors. 2025. DOI: 10.3390/bios15030174.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.