BACKGROUND

Cervical cytology screening is usually laborious with a heavy workload and poor diagnostic consistency. The authors have developed an artificial intelligence (AI) microscope that can provide onsite diagnostic assistance for cervical cytology screening in real time.

METHODS

A total of 2167 cervical cytology slides were selected from a cohort of 10,601 cases from Shenzhen Maternity and Child Healthcare Hospital, and the training data set consisted of 42,073 abnormal cervical epithelial cells. The recognition results of an AI technique were presented in a microscope eyepiece by an augmented reality technique. Potentially abnormal cells were highlighted with binary classification results in a 10× field of view (FOV) and with multiclassification results according to the Bethesda system in 20× and 40× FOVs. In addition, 486 slides were selected for the reader study to evaluate the performance of the AI microscope.

RESULTS

In the reader study, which compared manual reading with AI assistance, the sensitivities for the detection of low-grade squamous intraepithelial lesions and high-grade squamous intraepithelial lesions were significantly improved from 0.837 to 0.923 (P < .001) and from 0.830 to 0.917 (P < .01), respectively; the κ score for atypical squamous cells of undetermined significance (ASCUS) was improved from 0.581 to 0.637; the averaged pairwise κ of consistency for multiclassification was improved from 0.649 to 0.706; the averaged pairwise κ of consistency for binary classification was improved from 0.720 to 0.798; and the averaged pairwise κ of ASCUS was improved from 0.557 to 0.639.

CONCLUSIONS

The results of this study show that an AI microscope can provide real-time assistance for cervical cytology screening and improve the efficiency and accuracy of cervical cytology diagnosis.

Для цитирования: Tang Hong-Ping, Cai De, Kong Yan-Qing, Ye Hu, Ma Zhao-Xuan, Lv Huai-Sheng, Tuo Lin-Rong, Pan Qin-Jing, Liu Zhi-Hua, Han Xiao. Cervical cytology screening facilitated by an artificial intelligence microscope: A preliminary study.. Cancer cytopathology. 2021. DOI: 10.1002/cncy.22425.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.