[Brain death diagnosis after sedation with propofol or sufentanil. Recommendations for the usage of toxicological analytics].

Walter U, Brüderlein U, Gloger M, Mann S, Walther U

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Before the clinical diagnosis of brain death is made, toxicological analyses are often performed for the exclusion of effective serum levels of previously applied sedating drugs. For propofol and sufentanil there are no uniform recommendations for the usage of toxicology test results.

OBJECTIVES

To develop a standard practice in the diagnosis of brain death after therapeutic application of one of these drugs.

MATERIAL AND

METHODS

Based on the current literature and the available analytical assays, an ad hoc working group consisting of specialists in toxicology and intensive care medicine compiled recommendations for the usage of toxicological analytics in the diagnosis of brain death at the Rostock University Hospital.

RESULTS

For propofol, current analytical assays allow the quantification of serum concentrations of 0.2 μg/ml and lower; the execution of clinical brain death diagnostics is recommended by the ad hoc group only at propofol serum levels lower than  0.4 μg/ml. For sufentanil, the currently prevalent assays set lower determination limits of about 0.2 ng/ml in serum and 0.1 ng/ml in urine, which is above the cautiously adopted lower therapeutic serum concentration of 0.02 ng/ml. Therefore after negative determination of sufentanil (< 0.2 ng/ml) in blood serum, the following alternative procedures are recommended: (1) the execution of clinical brain death diagnostics under administration of naloxone; or (2) at intact renal function the additional negative determination of sufentanil in urine (< 0.1 ng/ml). If an assay allowing the detection of sufentanil at ≤ 0.01 ng/ml is available, brain death diagnostics should be carried out only at a serum level lower than  0.02 ng/ml.

CONCLUSION

These recommendations may serve as a proposal for similar standards in other hospitals.

Для цитирования: Walter U, Brüderlein U, Gloger M, Mann S, Walther U. [Brain death diagnosis after sedation with propofol or sufentanil. Recommendations for the usage of toxicological analytics].. Medizinische Klinik, Intensivmedizin und Notfallmedizin. 2014. DOI: 10.1007/s00063-014-0416-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.