Comparison of one- and 12-month outcomes of transcatheter aortic valve replacement in patients with severely stenotic bicuspid versus tricuspid aortic valves (results from a multicenter registry).

Kochman Janusz, Huczek Zenon, Scisło Piotr, Dabrowski Maciej, Chmielak Zbigniew, Szymański Piotr, Witkowski Adam, Parma Radosław, Ochala Andrzej, Chodór Piotr, Wilczek Krzysztof, Reczuch Krzysztof W, Kubler Piotr, Rymuza Bartosz, Kołtowski Lukasz, Scibisz Anna, Wilimski Radosław, Grube Eberhard, Opolski Grzegorz

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

The aim of the study was to evaluate the transcatheter aortic valve replacement (TAVR) in high-risk patients with severe bicuspid aortic valve (BAV) stenosis and to compare the outcomes with a matched group of patients with tricuspid aortic valve. TAVR became an alternative treatment method in high-risk patients with symptomatic aortic stenosis; however, BAV stenosis is regarded as a relative contraindication to TAVR. The study population comprised 28 patients with BAV who underwent TAVR. BAV was diagnosed based on a transesophageal echocardiography. CoreValve and Edwards SAPIEN prostheses were implanted. The control group consisted of 84 patients (3:1 matching) with significant tricuspid aortic valve stenosis treated with TAVR. There were no significant differences between patients with and without BAV in device success (93% vs 93%, p = 1.0), risk of annulus rupture (0% in both groups), or conversion to cardiosurgery (4% vs 0%, respectively, p = 0.25). The postprocedural mean pressure gradient (11.5 ± 6.4 vs 10.4 ± 4.5 mm Hg, p = 0.33), aortic regurgitation grade ≥2 of 4 (32% vs 23%, p = 0.45), 30-day mortality (4% vs 7%, p = 0.68), and 1-year all-cause mortality (19% vs 18%, p = 1.00) did not differ between the groups. Echocardiography showed well-functioning valve prosthesis with a mean prosthetic valve area of 1.6 ± 0.4 cm(2) versus 1.7 ± 0.3 cm(2) (p = 0.73), a mean pressure gradient of 10.3 ± 5.4 versus 9.8 ± 2.8 mm Hg (p = 0.64), and aortic regurgitation grade ≥2 of 4 (22% vs 22%, p = 1.00) for the 2 groups. In conclusion, selected high-risk patients with BAV can be successfully treated with TAVR, and their outcomes are similar to those reported in patients without BAV.

Для цитирования: Kochman Janusz, Huczek Zenon, Scisło Piotr, Dabrowski Maciej, Chmielak Zbigniew, Szymański Piotr, Witkowski Adam, Parma Radosław, Ochala Andrzej, Chodór Piotr, Wilczek Krzysztof, Reczuch Krzysztof W, Kubler Piotr, Rymuza Bartosz, Kołtowski Lukasz, Scibisz Anna, Wilimski Radosław, Grube Eberhard, Opolski Grzegorz. Comparison of one- and 12-month outcomes of transcatheter aortic valve replacement in patients with severely stenotic bicuspid versus tricuspid aortic valves (results from a multicenter registry).. The American journal of cardiology. 2014. DOI: 10.1016/j.amjcard.2014.05.063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.