MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2019.03.123

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2019

Experience of a single institution with femoral vein homograft as right ventricle to pulmonary artery conduit in stage 1 Norwood operation.

Kumar T K Susheel, Zurakowski David, Briceno-Medina Mario, Shah Aditya, Sathanandam Shyam, Allen Jerry, Sandhu Hitesh, Joshi Vijaya M, Boston Umar, Knott-Craig Christopher J

СтатьяVideo-Audio MediaПеревод в очереди

Аннотация

OBJECTIVE

Femoral vein homograft can be used be used as valved right ventricle to pulmonary artery conduit in the Norwood operation. We describe the results of this approach, including pulmonary artery growth and ventricular function.

METHODS

A retrospective chart review of 24 consecutive neonates with hypoplastic left heart syndrome or complex single ventricle undergoing this approach between June 2012 and December 2017 was performed. Conduit valve competency and ventricular function were estimated using transthoracic echocardiogram, and pulmonary artery growth was measured using Nakata's index. Changes in ventricular function pre-Glenn and at latest follow-up were assessed by ordinal logistic regression with a general linear model to account for the correlation within the same patient over time.

RESULTS

Median age at surgery was 4 days, and mean weight was 3 kg. There was no interstage mortality. A total of 21 patients have undergone Glenn operation, and 9 patients have completed the Fontan operation. None of the conduits developed thrombosis. Sixty-three percent of conduits remained competent in the first month, and 33% remained competent after 3 months of operation. Catheter interventions on conduits were necessary in 14 patients. Median Nakata index at pre-Glenn catheterization was 228 mm2/m2 (interquartile range, 107-341 mm2/m2). Right ventricular function was preserved in 83% of patients at a median follow-up of 34 (interquartile range, 10-46) months.

CONCLUSIONS

Femoral vein homograft as a right ventricle to pulmonary artery conduit in the Norwood operation is safe and associated with good pulmonary artery growth and preserved ventricular function as assessed by subjective echocardiography. Catheter intervention of the conduit may be necessary.

Для цитирования: Kumar T K Susheel, Zurakowski David, Briceno-Medina Mario, Shah Aditya, Sathanandam Shyam, Allen Jerry, Sandhu Hitesh, Joshi Vijaya M, Boston Umar, Knott-Craig Christopher J. Experience of a single institution with femoral vein homograft as right ventricle to pulmonary artery conduit in stage 1 Norwood operation.. The Journal of thoracic and cardiovascular surgery. 2019. DOI: 10.1016/j.jtcvs.2019.03.123.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.